Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13638740

- Product Categories
- Friendly Links
Information Name: | Zaozhuang electric floor heating material Franchise hot yoga studio gym heating |
Published: | 2015-05-19 |
Validity: | 3000000 |
Specifications: | 100 sq / m |
Quantity: | 1000000.00 |
Price Description: | |
Detailed Product Description: | Warm as the most comfortable way of heating, has been accepted by more and more owners, you as the owner, it is necessary to heat the floor to find out about the selection and installation of knowledge one, choose warm laminate flooring and flooring with the selected proposal the thickness of the multilayer wood flooring composite floor about 8-12MM, the thickness of the multilayer wood flooring mostly in 12-15MM, well as long as the insulation board to warm the use of quality, heat is not transmitted to the downstairs, wooden floors because the heat Block is great, but the ability to impede heat insulation board passed downstairs towards stronger, sooner or later will not penetrate the heat into the room back down the floor drain up, but if poor quality insulation board, it will turn the heat through the insulation board transfer to the downstairs, therefore, under the conditions of high-quality insulation board to warm temperatures and solid wood flooring Multilayered Flooring feeling there will be a big difference, and if you choose to heat the floor, you can use well-known brands of geothermal floor, These manufacturers strict requirements for the selection of the substrate, the strength of the same thickness, permeability, good heat dissipation, heat resistance after special treatment. Non-Dedicated to warm geothermal floor, as long as good quality, have a certain brand awareness, but also can be used to warm. Second, on the warm cement leveling material cement (425 # and 325 #) and sand (Coarse) ratio of not less than 1: 3, if the conditions it is best to add some beans stone to enhance the strength of the cement layer and thermal conductivity. Cement thickness control at 2-3.5 cm, at the end of the cement screed, preferably pure cement were again received light treatment to ensure the situation over sand flatness and will not appear cement surface, ground to 2 m radius of the range within must be level, the level of difference is not more than 3 mm. Third, with particular attention to the installation before floor drying cement screed flooring on the ground floor after leveling is complete, let the cement overlay natural drying, carried out in three days immediately prior to drying pavement floor heating less than 40 hours, so that cement layer in the water fully play out, to be substantially dry. Because otherwise impermeable insulation board, after heating to warm the cement floor, cement floor in a large number of water will evaporate out of the lower part attached to the floor, causing the floor of the deformation or discoloration caused by light-colored floor. Fourth, install the floor under the floor mat of choice should be good to use diathermy mats, general mats try to open the hole to facilitate cooling, floor mats primarily as moisture, noise and buffering effect, thermal conductivity than the foam mats slow, so we recommend that you choose a little thin mats (eg 2-3MM) and openings, if the ground is very smooth cement leveling the case, can not floor mats, but the premise is sure to ground the cement layer bake dry, and try to ensure that the level screed. V. Notes during the installation of the floor in the floor urging workers must not be drilled or install a nail fight on the ground, so as not to cause damage to the surface of the system, when installed baseboard, hit the nail position must be optimistic, especially below the thermostat to avoid the cold and warm leads or ground temperature sensor broke. Try to choose door wall suction aspiration without land, so far as possible to ensure that the ground is not opening. Six, floor coverings when the gap spacing the floor and the wall surrounding the processing of contraction joint reserve of not less than 0.8CM (with baseboard cover appropriate), and the bigger the better, in order to ensure the free thermal expansion of floor time Events gap. Seven floor heating to warm the first program should be gradual warming or long to warm slowly warming should not turned on, it is recommended warmed about 1 degree per hour, in order to prevent excessive heating wood cracking distortion occurs. Taking into account any floor has a case of thermal expansion deformation defects, consumers in the second year of using the heating system must be in strict accordance with the provisions of the order of the heating procedure gradual warming can not step in place, such as the first day only heated to 18 degrees Celsius, the first two days to heat up to 20 degrees Celsius, the third day was warmed to 22 degrees Celsius. Geothermal ground floor for cement floor temperature should not exceed 45 degrees Celsius, the floor surface temperature should not exceed 35 degrees Celsius. If you exceed this temperature, it will affect the life of the floor and use cycle. The average family winter indoor temperature reaches 20 degrees Celsius is very comfortable, so long as the normal temperature, it will not affect the use of geothermal floor in the coming year. |
Admin>>>
You are the 20825 visitor
Copyright © GuangDong ICP No. 10089450, Candal warm All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 20825 visitor
Copyright © GuangDong ICP No. 10089450, Candal warm All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility